实例介绍
Rohde&Schwarz 频谱仪操作手册(英文) 1145.5850系列 全英文,详细的操作方式,各类使用技巧
R&S FSH Contents Contents Specifications Safety Instructions Certificate of qualit EC-Certificate of conformity Support Center Address List of R&S Representatives Putting into Operation Front view 1.1 Putting into Operation 1.2 Unpacking the Instrument 1.2 Setting up the Instrument Switching on the Spectrum Analyzer 1.4 Spectrum Analyzer Connectors 1.5 Screen Settings Q Country-Specific Settings 1.10 Setting the Date and Time Setting the date .1.11 Setting the time 1.1 Charging the Battery...... 1.12 Selecting the Instrument Default Setup 1.13 External Reference /External Trigger Switchover 1.14 Controlling the rF Attenuator 1.15 Using a Preamplifier… 1.15 PIN Entr 1.17 Connecting Printers .1.19 Setting the Baud rate for Remote Control 1.21 Enabling Options 1.21 Checking the Installed options 1.22 1145.5973.12 E-15 Contents R&S FSH 2 Getting Started 2. Measurements on cw signals 2.1 Level measurement 2 Setting the Reference Level 量‘面 2.2 Frequency Measurements 2.3 Harmonic Measurements of a sinewave Signal 面面 2.4 Power Measurements Using the Power Sensor 2.5 Power and return loss measurements with the r&s FsH-z14 or the r&s FSH-Z444427 Two-Port Transmission measurements 2.9 Measurement of return loss 2.11 Performing Distance-To-Fault Measurements... 2.14 Operation in Receiver Mode 2.20 Measuring the carrier-to-Noise power ratio 2. Determining the Reference 2.26 St s…2.26 Selecting the reference channel 2.27 Entering the channel bandwidth of the reference channel 2.27 Selecting the unit for the reference... 2.27 Manually entering the reference 2.27 Automatic level adjustment 2.27 Measuring the Noise Power and Calculating Carrier Power /Noise Power.........2.28 Selecting the result display 2.28 Frequency setting of the noise channel.. 2.28 Setting the noise channel measurement bandwidth 2.29 Setting the C/N channel bandwidth 2.29 Automatic level adjustment 2.29 Correcting the displayed average noise level 2.30 Hiding the result display 2.30 Saving and Recalling Settings and Test Results 2.31 Saving Measurement Results 2.31 Saving Calibration Data 2.32 Recalling measurement results 2.33 Printing Out Measurement Results…… 2.34 1145.5973.12 2 E-15 R&S FSH Contents 3 Operation 3. Screen Layout Screen layout for spectrum-mode measurements without markers 3.1 Screen layout when the marker mode is selected 3.2 Entering Measurement Parameters Entering values and texts 3.3 Entering units 3.4 Menu overview .3.5 Frequency entry Frequency span... Level setting… 3.5 Bandwidth setting Trace setting 3.6 Measurement functions 3.7 Marke 3.10 Save and print menu 3.12 Instrument setup 3.12 Status display 3.12 Menus in the Receiver Mode(option R&S FSH-K3) 3.13 Menu for 3GPP BTS Code domain Power Measurement (Option R&S FSH-K4) 3.16 Menu for Vector Voltmeter(Option R&S FSH-K2) 3.16 1145.5973.12 E-15 Contents R&S FSH 4 Instrument functions 4 Instrument Default Setup 4.1 Status Display.................. 4.1 Setting the Frequency 4.2 Entering the center frequency. .4.2 Setting a frequency offset 4.2 Entering the center-frequency step size 4.3 Entering the start and stop frequency 4.4 Working with channel tables Setting the Span 1面 4.6 Setting the Amplitude Parameters 4.7 Setting the reference level Entering the display range 94.9 Entering the display unit 4.9 Entering the reference offset 4.10 Entering the input impedance.……… …4.10 Setting the Bandwidths 4.11 Resolution bandwidth 4.11 Video bandwidth 4.13 Setting the Sweep 4.14 Sweep time .4.15 Sweep mode .4.15 Trigger 4.16 Trace Settings 4.19 Trace mode ∴4.19 Detector 4.20 Trace memory… 4.22 Trace mathematics 4.23 Using the Markers 4.24 Automatic marker positioning ....... 4.25 Using more than one marker at a time(multimarker mode)......... ,4.27 Marker functions 4.30 Measuring the noise power density 4.30 Measuring the frequency 4.31 Measuring the filter bandwidth or the signal bandwidth 4.32 aF demodulation 4.33 1145.5973.12 E-15 R&S FSH Contents Using the dis play line…….….….….….….….….….…..….….……….…..34 Setting and Using the Measurement Functions 4.35 Measuring the channel power of continuously modulated signals………………4.35 Selecting the standard 4.36 Setting the reference level 4.38 Setting the channel bandwidth 4.38 Changing the spa Power displa Power measurements on TDMA signals 4.42 Selecting a standard ∴4.42 Setting the measurement time 4.44 Optimizing the reference level .. 4.44 Power readout 4.45 Setting the trigger 4.45 Measuring the occupied bandwidth 4.46 Selecting a standard 4.47 Setting the reference level 4.48 Setting the channel bandwidth 4.49 Entering the power percent to determine the occupied bandwidth 4.50 Displaying th upied bandwidth 4.50 Changing the spai 1145.5973.12 E-15 Contents R&S FSH Measuring the Carrier-to-Noise Ratio....... 4.52 Determining the reference 4.53 Setting the reference channel 4.53 Setting the reference channel bandwidth…… 4.53 Setting the analyzer reference level for the reference channel measurement 4.54 Manual reference mode 4.54 Inserting the c/N reference Units of the c/n reference 4.55 Standards USER Standard 4.56 User-specific standards 4.56 Predefined user-specific standards 4.59 Predefined user-specific standard Digital TX 4.59 Predefined user-specific standard ANalog tv mode 4.60 Predefined user-specific standard ctx 4.60 Measuring the noise channel power and calculating the carrier power/noise power .4.62 Frequency setting of the noise channel……… 4.63 Setting the noise channel bandwidth 4.64 Setting the C/N ratio channel bandwidth 4.64 Setting the reference level during noise channel measurement .4.65 Selecting the c/ N result display..…,… 4.65 C/N measurement result display 4.66 Changing the span 4.66 Correction of inherent noise power 4.67 Using the R&S FSH in receiver mode 4.68 Setting the frequency Setting the reference level ,,,。 .。 4.71 Setting the bandwidth 4.72 Setting the detector 4.73 Setting the measurement time 4.73 Measurement on multiple frequencies or channels(scan) 4.74 Measurements using the power sensor 4.76 Connecting the power sensor…… 4.76 Zeroing the power sensor .4.78 Selecting the unit for the power readout 4.79 Setting the averaging time.…… 4.80 Taking additional loss or gain into account 4.81 Measuring forward and reflected power ∴4.82 Zeroing the power sensor 4.84 Setting the power measurement weighting 4.85 Selecting the unit for the power readout 4.86 Taking additional attenuation into account 4.88 1145.5973.12 6 E-15 R&S FSH Contents Two-port measurements with the tracking generator 489 Measuring the transmission of two-ports 4.91 Vector transmission measurement 494 Measuring the transmission magnitude........ 4.96 Measuring the transmission phase 4.96 Measuring the electrical length when measuring transmission 面B国 4.99 Measuring the group delay when measuring transmission 4.100 Transmission measurement using the connected VSWR Bridge R&S FSH-Z3.. 4.102 Sp pectrum measurements with the VsWR Bridge R&s FSH-Z3 or R&S FSH-Z2 connected Setting for detecting the R&S FSH-Z3 in the transm. and spectr. measurement .. 4.104 Supplying DC voltage to active DUTs 4.105 Reflection measurements 4.105 Scalar measurement of reflection 4.106 Vector measurement of reflection 4.108 Measuring the reflection magnitude 4.111 Measuring the reflection phase.…… 4.111 Measuring the electrical length when measuring reflection 4.112 Displaying the reflection in the Smith chart 4.113 Measuring the group delay when measuring reflection 4.118 Selecting the calibration standards 4.120 Spectrum measurements with the vswr Bridge r&s FSH-Z3 or R&S FSH-z2 connected 4.121 Settings for detection of the R&SFSH-z2andR&SFSH-Z3……… 4.122 One-Port measurement of cable loss 4.123 Vector voltmeter .4.124 Reflection measurements(S11) 4.125 Measuring transmission coefficients(S21) 4.128 Cable measurements 4.134 Cable selection ∴4.135 Selecting the frequency range …4.138 Calibrating the test setup a.::::::.“1 4.139 Locating cable faults by means of the marker function 4.142 Measuring spectrum and reflection 4.145 Further information ∴4.146 Setting the span 4.146 Selecting the center frequency......... ∴4.147 Measurement 4.148 Length measurement accuracy 4.148 Using limit Lines ∴4.149 Measurements with limit lines 国面面 4.151 Definition range of limit lines 4.152 Data sets containing limit lines... 4.152 1145.5973.12 7 Contents R&S FSH Measuring with Transducer Factors. 4.153 Unit for measurements with transducers 4.156 Reference level settings for measurements with transducers 4.156 Frequency range of transducer……… 4.156 Data sets containing transducer factors 4.156 Field-Strength Measurement with Isotropic Antenna ∴4.157 Connecting the antenna to the R&S FSH 4.157 Measurement of the resultant field strength in a transm. channel with large bandwidth .......4.159 Code Domain Power Measurement on 3GPP FDD Signals .4.166 Saving and Loading Instrument Settings and Measurement Results 4.173 Saving results 4.174 Entering a data set name 4.175 Loading measurement results .4.175 Deleting saved data sets 4.176 Deleting all data sets 4.177 Printing out Measurement Results 4.178 Measurements 4.179 How a spectrum analyzer operates …4.179 1145.5973.12 E-15 【实例截图】
【核心代码】
标签:
小贴士
感谢您为本站写下的评论,您的评论对其它用户来说具有重要的参考价值,所以请认真填写。
- 类似“顶”、“沙发”之类没有营养的文字,对勤劳贡献的楼主来说是令人沮丧的反馈信息。
- 相信您也不想看到一排文字/表情墙,所以请不要反馈意义不大的重复字符,也请尽量不要纯表情的回复。
- 提问之前请再仔细看一遍楼主的说明,或许是您遗漏了。
- 请勿到处挖坑绊人、招贴广告。既占空间让人厌烦,又没人会搭理,于人于己都无利。
关于好例子网
本站旨在为广大IT学习爱好者提供一个非营利性互相学习交流分享平台。本站所有资源都可以被免费获取学习研究。本站资源来自网友分享,对搜索内容的合法性不具有预见性、识别性、控制性,仅供学习研究,请务必在下载后24小时内给予删除,不得用于其他任何用途,否则后果自负。基于互联网的特殊性,平台无法对用户传输的作品、信息、内容的权属或合法性、安全性、合规性、真实性、科学性、完整权、有效性等进行实质审查;无论平台是否已进行审查,用户均应自行承担因其传输的作品、信息、内容而可能或已经产生的侵权或权属纠纷等法律责任。本站所有资源不代表本站的观点或立场,基于网友分享,根据中国法律《信息网络传播权保护条例》第二十二与二十三条之规定,若资源存在侵权或相关问题请联系本站客服人员,点此联系我们。关于更多版权及免责申明参见 版权及免责申明
网友评论
我要评论