在好例子网,分享、交流、成长!
您当前所在位置:首页C# 开发实例C#网络编程 → C#和西门子PLC通讯例子源码C# VB例子都有

C#和西门子PLC通讯例子源码C# VB例子都有

C#网络编程

下载此实例
  • 开发语言:C#
  • 实例大小:0.56M
  • 下载次数:78
  • 浏览次数:776
  • 发布时间:2019-08-16
  • 实例类别:C#网络编程
  • 发 布 人:pzh
  • 文件格式:.rar
  • 所需积分:2
 相关标签: 通讯 C#

实例介绍

【实例简介】
【实例截图】
【核心代码】
WinTcpS7_CP2.PlcClient PLC = new WinTcpS7_CP2.PlcClient();
  bool EntLink;
  long ScanCount;
  short ScanRet;
  bool ScanRun;
        IntPtr PlcHand;
  [DllImport("winmm.dll", ExactSpelling=true, CharSet=CharSet.Ansi, SetLastError=true)]
  public static extern UInt32 timeGetTime();
  
  public void Form1_Load(System.Object sender, System.EventArgs e)
  {
   short i = 0;
   this.CenterToScreen();
   cmbReadMry.Items.Clear();
   cmbReadMry.Items.Add("DI");
   cmbReadMry.Items.Add("DQ");
   cmbReadMry.Items.Add("MR");
   cmbReadMry.Items.Add("DR");
   cmbWriteMry.Items.Clear();
   cmbWriteMry.Items.Add("DI");
   cmbWriteMry.Items.Add("DQ");
   cmbWriteMry.Items.Add("MR");
   cmbWriteMry.Items.Add("DR");
   cmbBitMry.Items.Clear();
   cmbBitMry.Items.Add("DI");
   cmbBitMry.Items.Add("DQ");
   cmbBitMry.Items.Add("MR");
   cmbReadType.Items.Clear();
   cmbReadType.Items.Add("INT16");
   cmbReadType.Items.Add("UINT16");
   cmbReadType.Items.Add("DINT32");
   cmbReadType.Items.Add("HEX32");
   cmbReadType.Items.Add("REAL32");
   cmbReadType.Items.Add("BIN16");
   cmbWriteType.Items.Clear();
   cmbWriteType.Items.Add("INT16");
   cmbWriteType.Items.Add("UINT16");
   cmbWriteType.Items.Add("DINT32");
   cmbWriteType.Items.Add("HEX32");
   cmbWriteType.Items.Add("REAL32");
   cmbWriteType.Items.Add("BIN16");
   
   for (i = 0; i <= 15; i )
   {
    cmbBit.Items.Add("Bit" System.Convert.ToString(i));
   }
   cmbReadMry.SelectedIndex = 3;
   cmbWriteMry.SelectedIndex = 3;
   cmbBitMry.SelectedIndex = 0;
   cmbBit.SelectedIndex = 0;
   cmbReadType.SelectedIndex = 0;
   cmbWriteType.SelectedIndex = 0;
   lstRead.Items.Clear();
   txtWrite.Text = "";
   
  }
  
  
  public void butLink_Click(System.Object sender, System.EventArgs e)
  {
   short re = 0;
   string restr = "";
            re = PLC.EntLink(txtLocalIP.Text.Trim(), Convert.ToUInt16(txtLocalPort.Text), txtRemoteIP.Text.Trim(), (Convert.ToUInt16(txtRemotePort.Text)), "", "", "DEMO", ref PlcHand);
   txtReLink.Text = re.ToString();
   if (re == 0)
   {
    EntLink = true;
    MessageBox.Show("PLC联接成功!");
   }
   else
   {
    EntLink = false;
    MessageBox.Show("PLC联接失败: " restr);
   }
  }
  
  public void butClose_Click(System.Object sender, System.EventArgs e)
  {
   short re = 0;
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
            re = PLC.DeLink(PlcHand);
   txtReClose.Text = re.ToString();
  }
  
  public void butRead_Click(System.Object sender, System.EventArgs e)
  {
   short i = 0;
   object[] RD = null;
   RD = new object[Convert.ToUInt16(txtReadCnt.Text)];
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   int var1 = cmbReadType.SelectedIndex 1;
            WinTcpS7_CP2.PlcClient.DataType typ = (WinTcpS7_CP2.PlcClient.DataType)var1;
   switch (cmbReadMry.SelectedIndex)
   {
    case 0:
                    ScanRet = PLC.CmdRead(PlcHand,WinTcpS7_CP2.PlcClient.PlcMemory.DI, typ,   Convert.ToUInt16(txtReadAdd.Text), Convert.ToUInt16(txtReadCnt.Text), ref RD);
     break;
    case 1:
                    ScanRet = PLC.CmdRead(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DQ, typ, Convert.ToUInt16(txtReadAdd.Text), Convert.ToUInt16(txtReadCnt.Text), ref RD);
     break;
    case 2:
                    ScanRet = PLC.CmdRead(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.MR, typ, Convert.ToUInt16(txtReadAdd.Text), Convert.ToUInt16(txtReadCnt.Text), ref RD);
     break;
    case 3:
                    ScanRet = PLC.CmdRead(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DR, typ, Convert.ToUInt16(txtReadAdd.Text), Convert.ToUInt16(txtReadCnt.Text), ref RD);
     break;
   }
   txtReRead.Text = ScanRet.ToString();
   lstRead.Items.Clear();
   for (i = 0; i <= (RD.Length - 1); i )
   {
    if (!(RD[i] == null))
    {
     lstRead.Items.Add(RD[i]);
    }
    else
    {
     lstRead.Items.Add("0");
    }
   }
   
  }
  
  
  public void butWrite_Click(System.Object sender, System.EventArgs e)
  {
   short i = 0;
   string[] temp = null;
   object[] WD = null;
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   WD = new object[Convert.ToUInt16(txtWriteCnt.Text)];
   temp = txtWrite.Text.Split('\n');
   for (i = 0; i <= (WD.Length - 1); i )
   {
    if (i > (temp.Length - 1))
    {
     WD[i] = 0;
    }
    else
    {
     WD[i] = temp[i].Trim();
    }
   }
   int var1 = cmbWriteType.SelectedIndex 1;
            WinTcpS7_CP2.PlcClient.DataType typ = (WinTcpS7_CP2.PlcClient.DataType)var1;
   switch (cmbWriteMry.SelectedIndex)
   {
    case 0:
                    ScanRet = PLC.CmdWrite(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DI, typ, Convert.ToUInt16(txtWriteAdd.Text), Convert.ToUInt16(txtWriteCnt.Text), ref WD);
     break;
    case 1:
                    ScanRet = PLC.CmdWrite(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DQ, typ, Convert.ToUInt16(txtWriteAdd.Text), Convert.ToUInt16(txtWriteCnt.Text), ref WD);
     break;
    case 2:
                    ScanRet = PLC.CmdWrite(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.MR, typ, Convert.ToUInt16(txtWriteAdd.Text), Convert.ToUInt16(txtWriteCnt.Text), ref WD);
     break;
    case 3:
                    ScanRet = PLC.CmdWrite(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DR, typ, Convert.ToUInt16(txtWriteAdd.Text), Convert.ToUInt16(txtWriteCnt.Text), ref WD);
     break;
   }
   txtReWrite.Text = ScanRet.ToString();
  }
  
  public void butScan_Click(System.Object sender, System.EventArgs e)
  {
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   if (butScan.Text == "Cycle R/W")
   {
    ScanCount = 0;
    ScanRun = true;
    Timer1.Enabled = true;
    butScan.Text = "Stop R/W";
   }
   else
   {
    ScanRun = false;
    Timer1.Enabled = false;
    butScan.Text = "Cycle R/W";
   }
  }
  
  public void Timer1_Tick(System.Object sender, System.EventArgs e)
  {
   if (!ScanRun)
   {
    butScan_Click(null, null);
    return;
   }
   int tim = System.Convert.ToInt32(timeGetTime());
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   //
   butRead_Click(null, null);
   if (ScanRet < 0)
   {
    ScanRun = false;
    return;
   }
   butWrite_Click(null, null);
   if (ScanRet < 0)
   {
    ScanRun = false;
    return;
   }
   //
   ScanCount ;
   txtScanCnt.Text = ScanCount.ToString();
   txtScanPrd.Text = (System.Convert.ToInt32(timeGetTime()) - tim).ToString() "ms";
  }
  
  
  public void butBitTest_Click(System.Object sender, System.EventArgs e)
  {
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   bool rd = false;
   short re = 0;
   switch (cmbBitMry.SelectedIndex)
   {
    case 0:
                    re = PLC.Bit_Test(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DI, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex), ref rd);
     break;
    case 1:
                    re = PLC.Bit_Test(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DQ, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex), ref rd);
     break;
    case 2:
                    re = PLC.Bit_Test(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.MR, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex), ref rd);
     break;
   }
   txtBitTest.Text = rd.ToString();
   txtReBit.Text = re.ToString();
  }
  
  public void butBitSet_Click(System.Object sender, System.EventArgs e)
  {
   if (!EntLink)
   {
    MessageBox.Show("还未与PLC建立联接!");
    return;
   }
   short re = 0;
   switch (cmbBitMry.SelectedIndex)
   {
    case 0:
                    re = PLC.Bit_Set(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DI, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex));
     break;
    case 1:
                    re = PLC.Bit_Set(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.DQ, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex));
     break;
    case 2:
                    re = PLC.Bit_Set(PlcHand, WinTcpS7_CP2.PlcClient.PlcMemory.MR, Convert.ToUInt16(txtBitAdd.Text), Convert.ToUInt16(cmbBit.SelectedIndex));
     break;
   }
   txtReBit.Text = re.ToString();
  }

标签: 通讯 C#

实例下载地址

C#和西门子PLC通讯例子源码C# VB例子都有

不能下载?内容有错? 点击这里报错 + 投诉 + 提问

好例子网口号:伸出你的我的手 — 分享

网友评论

发表评论

(您的评论需要经过审核才能显示)

查看所有0条评论>>

小贴士

感谢您为本站写下的评论,您的评论对其它用户来说具有重要的参考价值,所以请认真填写。

  • 类似“顶”、“沙发”之类没有营养的文字,对勤劳贡献的楼主来说是令人沮丧的反馈信息。
  • 相信您也不想看到一排文字/表情墙,所以请不要反馈意义不大的重复字符,也请尽量不要纯表情的回复。
  • 提问之前请再仔细看一遍楼主的说明,或许是您遗漏了。
  • 请勿到处挖坑绊人、招贴广告。既占空间让人厌烦,又没人会搭理,于人于己都无利。

关于好例子网

本站旨在为广大IT学习爱好者提供一个非营利性互相学习交流分享平台。本站所有资源都可以被免费获取学习研究。本站资源来自网友分享,对搜索内容的合法性不具有预见性、识别性、控制性,仅供学习研究,请务必在下载后24小时内给予删除,不得用于其他任何用途,否则后果自负。基于互联网的特殊性,平台无法对用户传输的作品、信息、内容的权属或合法性、安全性、合规性、真实性、科学性、完整权、有效性等进行实质审查;无论平台是否已进行审查,用户均应自行承担因其传输的作品、信息、内容而可能或已经产生的侵权或权属纠纷等法律责任。本站所有资源不代表本站的观点或立场,基于网友分享,根据中国法律《信息网络传播权保护条例》第二十二与二十三条之规定,若资源存在侵权或相关问题请联系本站客服人员,点此联系我们。关于更多版权及免责申明参见 版权及免责申明

;
报警